Product

Agilent 1200 Series High-Performance Liquid Chromatography (HPLC) System

Agilent 1200 Series High-Performance Liquid Chromatography (HPLC) System

The Agilent 1200 Series HPLC system, introduced by Agilent Technologies Inc., is a classic, modular, and high-performance liquid chromatography system. Renowned for its exceptional reliability, superior performance, and high flexibility, it is widely used for qualitative and quantitative analysis across numerous fields including pharmaceuticals, biotechnology, environmental monitoring, food testing, and chemical industries. The following provides a detailed introduction to the system's modules and their overall functionality, based on the provided configuration list.

Price:Negotiable

Service charge: 10% of the transaction price

  • Equipment brandAgilent 
  • Equipment installation time:2021
  • Equipment location:Shanghai
  • Equipment model:Agilent 1200 Series High-Performance Liquid Chromatography (HPLC) System
  • Equipment serial number
  • Voltage:220V
  • Electrical frequency
  • Size
  • Weight

Device built-in

Agilent 1200 Series High-Performance Liquid Chromatography (HPLC) System

The Agilent 1200 Series HPLC system, introduced by Agilent Technologies Inc., is a classic, modular, and high-performance liquid chromatography system. Renowned for its exceptional reliability, superior performance, and high flexibility, it is widely used for qualitative and quantitative analysis across numerous fields including pharmaceuticals, biotechnology, environmental monitoring, food testing, and chemical industries. The following provides a detailed introduction to the system's modules and their overall functionality, based on the provided configuration list.

I. Overall System Overview

The configured Agilent 1200 Series HPLC system represents a fully-featured, high-performance standard analytical platform. It integrates all core components of liquid chromatography: sample introduction, high-pressure solvent delivery, chromatographic separation, online degassing, multi-mode detection, precise temperature control, as well as data acquisition and processing. This system is capable of handling a variety of analytical tasks, from routine quality control and method development to the analysis of complex samples. Its modular design also allows for future functional expansion and upgrades.

II. Detailed Functions and Features of Core Modules

G1322A Degasser: The Foundation for Stable Analysis

  • Function:Removes dissolved gases from the mobile phase online. These gases can form bubbles within the flow path, leading to unstable pump flow rates, increased baseline noise in the detector, and signal drift, all of which severely interfere with analytical results.

  • Importance:The degasser is a critical component for ensuring stable system operation and obtaining a smooth baseline. Utilizing a special membrane tube permeation principle, it efficiently removes oxygen and bubbles from the solvents, providing a stable, interference-free liquid environment for the entire analytical process.

G1311A Quat Pump: The Core for Accurate Flow and Gradient Delivery

  • Function:Acting as the "heart" of the system, it delivers the mobile phase at high pressure, with precision and minimal pulsation.

  • Features:As a quaternary gradient pump, it can accommodate four different solvents connected to a single pump unit. Through precise proportioning valve control, it enables complex gradient elution programs. This is crucial for separating samples with complex compositions and significantly differing polarities, effectively enhancing resolution and reducing analysis time.

G1329A Autosampler (ALS) and G1330B ALS Thermostat: An Efficient and Precise Sample Introduction Platform

  • G1329A ALS Function:Enables automated and precise sample introduction, replacing tedious and less reproducible manual injection.

  • Advantages:Offers high injection precision and accuracy, supports various injection volumes and different vial formats, significantly improving analytical efficiency. It is particularly suited for the continuous analysis of large sample batches and ensures highly reproducible data.

  • G1330B ALS Thermostat Function:Provides independent temperature control for the autosampler's sample tray.

  • Importance:For temperature-sensitive samples (e.g., biological samples), it ensures their chemical stability while awaiting injection, preventing degradation or deterioration, thereby guaranteeing the accuracy and reliability of analytical results.

G1316A Column Compartment (TCC): Ensuring Reproducibility in Chromatographic Separation

  • Function:Provides a precise and stable temperature environment for the chromatography column.

  • Importance:Column temperature is a key factor affecting retention time, separation efficiency, and peak shape. The TCC, through precise temperature control, significantly improves retention time reproducibility, optimizes separation selectivity, and aids in achieving symmetrical chromatographic peaks. It is essential for method transfer and long-term stable operation.

G1315D Diode Array Detector (DAD) and G1321A Fluorescence Detector (FLD): Powerful Multi-Dimensional Detection Capability

  • G1315D DAD Function:A UV-Vis detector capable of simultaneously acquiring full spectral information across a specified wavelength range.

  • Advantages:Compared to fixed-wavelength detectors, the DAD offers significant benefits. It not only performs quantitative analysis but also allows for peak purity assessment and compound identification based on the acquired spectra, providing stronger evidence for result confirmation. It is particularly suitable for unknown compound screening, peak purity testing, and analyzing samples with unknown maximum absorption wavelengths.

  • G1321A FLD Function:A highly sensitive and selective detector specifically designed for analyzing substances that possess native fluorescence or can be derivatized to produce fluorescence.

  • Advantages:FLD sensitivity is typically 1 to 3 orders of magnitude higher than that of UV detectors, making it especially suitable for trace analysis, such as the detection of drug metabolites, PAHs (Polycyclic Aromatic Hydrocarbons), amino acids, vitamins, etc. Its high selectivity effectively minimizes interference from complex matrices.

PC and Software: The Intelligent Control and Data Processing Center

  • The system is controlled by a dedicated PC workstation running professional chromatography data system software, such as Agilent's ChemStation.

  • Function:The software enables centralized control of all instrument modules (method editing, sequence setup, instrument status monitoring), real-time data acquisition, chromatographic data processing, quantitative calculation, and report generation. Its intuitive interface and powerful capabilities make method development, daily operation, and data analysis efficient and user-friendly.

III. Summary

In summary, the configured Agilent 1200 Series HPLC system establishes a stable mobile phase foundation through the G1322A Degasser and G1311A Quat Pump. It achieves precise sample introduction and separation environment control via the G1329A Autosampler (with the G1330B Thermostat) and the G1316A Column Compartment (TCC). Finally, it delivers powerful and flexible multi-dimensional detection capabilities through the complementary performance of the G1315D DAD and G1321A FLD detectors. This configuration can be considered a "gold standard" setup, capable of meeting the demands of routine high-throughput quality control while also possessing the robust ability to handle complex samples and conduct method development. It is an ideal choice for laboratories requiring efficient and reliable liquid chromatographic analysis.


Email:newlife@yinzhisci.com

Tel:021-65381707