Device built-in
Comprehensive Analysis of Agilent 6560 IM-Q-TOF LC/MS System
The Agilent 6560 Ion Mobility Q-TOF LC/MS system represents the world's first uniform field ion mobility mass spectrometer, integrating ultra-high performance liquid chromatography (UHPLC), ion mobility separation (IM), and high-resolution quadrupole time-of-flight mass spectrometry (Q-TOF) technologies. This innovative platform delivers unprecedented fourth-dimensional separation capability and novel structural information for complex sample analysis.
System Configuration and Core Technologies
The 6560 system comprises three key technological modules:
- Ion Mobility Separation Module:
- Features an 80cm uniform DC field drift tube with minimal ion heating effects to preserve biomolecular native conformations
- Innovative electrodynamic ion funnel technology provides 10x sensitivity improvement over conventional designs
- Delivers ion mobility resolution of 200 (FWHM), capable of separating ions with just 1% difference in collision cross-section
- Quadrupole-Time-of-Flight Mass Spectrometer Module:
- Mass range: 20-20,000 m/z with 42,000 resolution (FWHM @ m/z 2722)
- Mass accuracy: 1 ppm RMS (MS mode), 2 ppm RMS (MS/MS mode)
- Acquisition rates: 50 spectra/sec (MS), 30 spectra/sec (MS/MS)
- Liquid Chromatography Module:
- Standard 1290 Infinity II UHPLC system
- Perfect compatibility with ion mobility while maintaining chromatographic resolution at 5Hz acquisition speed
Performance Advantages and Innovative Features
The 6560 system incorporates several revolutionary technological breakthroughs:
- Multidimensional Separation Capability:
- Adds ion mobility dimension, increasing peak capacity by 10-100x
- Resolves isomeric compounds (lipids, polysaccharides) indistinguishable by conventional LC-MS
- Successfully separated three carbamazepine epoxide isomers in antiepileptic drug research
- Precise Structural Elucidation:
- Directly measures collision cross-sections (CCS) with <1% error without standards
- High-resolution demultiplexing (HRdm 2.0) improves dynamic range by one order of magnitude
- Supports collision-induced unfolding (CIU) for protein conformation studies
- Operational Convenience:
- VacShield technology enables capillary replacement without venting vacuum
- Includes professional data processing software (MassHunter BioConfirm)
- Temperature-mass stability of 1 ppm/3°C ensures data reproducibility
Key Application Areas
With its unique multidimensional separation capability, the 6560 system has become the ideal platform for cutting-edge research:
- Metabolomics: Comprehensive coverage of low-abundance metabolites for novel biomarker discovery
- Lipidomics: Differentiation of sn-position isomers and double-bond positional isomers
- Biopharmaceuticals: Antibody-drug conjugate (ADC) characterization and protein higher-order structure studies
- Environmental Analysis: Screening and identification of emerging contaminants in complex matrices
- Clinical Research: Therapeutic drug monitoring (TDM) with improved detection accuracy
At Vanderbilt University, the 6560 system demonstrated significantly improved analytical selectivity for 14 antiepileptic drugs compared to conventional LC-MS/MS, providing reliable data for precision medication.
The Agilent 6560 IM-Q-TOF system represents the pinnacle of multidimensional mass spectrometry technology. Its innovative separation capabilities and structural elucidation approaches have opened new research pathways in life sciences and precision medicine.